Input assembly address 24 to 51, Statistics information -17 – KEYENCE IV Series User Manual

Page 39

Advertising
background image

3-17

- IV Series User’s Manual (Field Network) -

Data allocation in the cyclic communication

z

„

Input Assembly Address 24 to 51: Statistics information

The Bits at Address 24 to 51 of the Input Assembly have the following functions:

Address

Data

type*

Item

Content

Data content

24 to 25

UINT

Processing time MAX

Displays the maximum

processing time value.

0 to 10000

26 to 27

UINT

Processing time MIN

Displays the minimum

processing time value.

0 to 10000

28 to 29

UINT

Processing time AVE

Displays the average processing

time value.

0 to 10000

30 to 31

---

Reserved by system

---

---

32 to 35

UDINT Number of triggers

Displays the total number of

triggers issued.

0-999999999

36 to 39

UDINT Number of OKs

Displays the total number of

triggers issued whose overall

status result was “OK”.

0-999999999

40 to 43

UDINT Number of NGs

Displays the total number of

triggers issued whose overall

status result was “NG”.

0-999999999

44 to 47

UDINT Number of trigger errors Number of triggers issued that

generated a trigger error

0-999999999

48 to 51

---

Reserved by system

---

---

* UINT : Unsigned 16-bit integer

UDINT : Unsigned 32-bit integer

y

The unit of processing time is msec.

y

The maximum number of triggers is 999999999. If the maximum value is exceeded, it will go back to 0

and start counting up again.

y

The maximum value for the number of OK triggers, number of NG triggers, and the number of trigger

errors is 999999999. The value will stop updating when the upper limit value is reached.

y

A reset will occur in the following conditions:

y

When [Statistics reset] is input

y

When a tool is added/deleted/copied

y

When the enable/disable status of the upper threshold value for the color area/area tool or the setting

scale has been changed via user operation or tool auto-tuning

y

When a tool auto-tuning is started with two or more tools other than the position correction tool set

y

When the sensor is switched OFF

y

When the program is switched

y

When a correction for the sensor is started

y

When the sensor is initialized

3

Cyclic communication

Advertising