5

E BL-1300-IM

Mounting the BL-1300 Series without the mounting

bracket

1

Fasten the BL-1300 Series.

Fasten the BL-1300 Series in the mounting position with M3 screws.

* The M3 screws are not included. Select the M3 screws after checking

the panel thickness and other factors of the mounting position.
(The mounting hole for the BL-1300 Series is 4 mm deep.)

Main unit (BL-1300/1301/1300HA/1301HA/1370/1371)

Main unit (BL-1350HA/1351HA)

Mounting bracket

* On the bottom of the mounting bracket, an insulation sheet is attached.

Do not remove it.

For the front type

For the side type

Note

To suppress the influence of noise, mount the insulation
plate between the unit and the place it will be mounted. If
the insulation plate is not mounted, a reading error or an
incorrect reading may occur.

Dimensions

BL-1300/1301/1300HA/

1301HA/1370/1371

BL-1350HA/1351HA

Mounting screw (M3)

Mounting screw (M3)

Mounting
hole

Mounting
hole

4.2

29.75

22.5

3.5

33

3.5

11.5

14.55

21

31

29.33

40

3.8

15.95

23.46

Laser beam

2-M 3 Depth 4

Center of
scanning

15

mi

n.

Cable length: 1.8 m

4.2

18.66

48

11.5

3.5

38.1

6.45

21

22

3.5

17.6

48

3.8

41.56

23.47

15°

Laser
beam

2-M 3

Depth4

Cable length: 2 m

15 m

in.

Center of
scanning

25

7.82

43.35

2.2

59.6

19.6

3

5.5

5.5

9

14

37.6

38.65

2-R 2.75

R19

2-R 2.75

10°

15°

2.2

40

6

26.5

35

.3

3

6.5

5.3

32.7

11.4

49.35

43.58

28.01

2-R 2.65

2-R 2.65

15

°

Mounting bracket A

Mounting bracket B

Laser
beam

Laser beam

18.66

2.2

1.6

21

19.6

67.6

48

21

3

11

38.5

5.3

5.3

5.5

36

3

41.56

2-R 2.65

2-R
2.65

15°

Advertising