The external CV inputs of the ADE-10 should accept any CV, LFO or audio signal within a range
of approximately +/-10V, however, CV content outside the range of 0-5V DC will be clipped
and blocked internally.
The diagram below shows how a single +/-5V (10V peak to peak) AC sine wave used as an external
CV input can be attenuated and/or biased via the front panel controls to modulate within the internal
0-5V DC CV range with no need for PCB ‘jumpers’ or external signal conditioning.
n.b. For this diagram, ‘bias’ refers to the manual modulation control (e.g. STAGE 1 MOD) for each

stage and ‘level’ refers to the external CV input control (e.g. STAGE 1 CV) for each stage.

© 2011 Abstract Data Ltd.

http://www.abstractdata.biz

[email protected]

Version 1.0 October 2011

6: CV

CV BIAS: 0%
CV LEVEL: 0%

0V

5V

-5V

0V

5V

-5V

0V

5V

-5V

CV BIAS: 50%
CV LEVEL: 0%

CV BIAS: 75%
CV LEVEL: 0%

CV BIAS: 0%
CV LEVEL: 50%

CV BIAS: 50%
CV LEVEL: 50%

CV BIAS: 75%
CV LEVEL: 50%

CV BIAS: 0%
CV LEVEL: 75%

CV BIAS: 50%
CV LEVEL: 75%

CV BIAS: 75%
CV LEVEL: 75%

0V

5V

-5V

CV BIAS: 0%
CV LEVEL: 100%

CV BIAS: 50%
CV LEVEL: 100%

CV BIAS: 75%
CV LEVEL: 100%

CV BIAS: 100%
CV LEVEL: 0%

CV BIAS: 100%
CV LEVEL: 50%

CV BIAS: 100%
CV LEVEL: 75%

CV BIAS: 100%
CV LEVEL: 100%