Ae rco, Appendix g, Leg e nd – AERCO BMK 2.0 LN Nat. Gas User Manual

Page 94

Advertising
background image

APPENDIX G

G-2

5)

THI

S

IS

A

TYPI

CAL

IN

STALL

A

TI

ON DRA

W

ING.

LOCAL

CODE

S A

ND AU

THORI

T

IE

S

SHOUL

D

B

E

CONS

ULTED.

CONVENI

E

NT FLOOR DRAI

N

. RELI

EF VAL

VE

S

H

OULD BE PI

P

E

D

V

E

RTI

C

ALLY

TO A HEI

G

HT 18'' ABOVE

FL

OOR.

FI

TTI

NGS TO

P

R

EVENT I

N

TERFER

ENCE W

ITH REMOVAL

OF BOI

LER PANEL

S

A

ND

COV

E

RS.

ALL

PI

PI

NG AND

ELE

C

TRI

C

CONNE

CTI

O

NS

(

SERVI

CE SW

IT

CHES,

CONDUI

T BOXES)

SHOULD LI

KEW

ISE

B

E

6

" AW

AY FROM SI

D

E

PA

NELS.

1)

FOR ACTUA

L SI

Z

ES

A

ND

L

O

CATI

ONS OF

P

IPI

NG AND OTHER CONNECTI

O

NS TO

T

H

E

B

O

IL

ER,

SEE

DI

MENSI

O

NAL DRAWI

NG

(AP-

A-

7

39)

.

3

) ALL (

*)

IT

EMS ARE I

NCLUDED SEPA

RATELY

IN

SHI

P

MENT FROM

F

A

CTORY.

NOT

ES:

AI

R

SEP

ARATOR

AUTOMA

TI

C

AI

R VENT

1-

1/

2"

N

P

T

DRAI

N

CONN.

LIN

E

SI

Z

E

BYPAS

S

BAC

KFLOW

PREVENTE

R

DI

APHRA

GM

TYP

E

EXP

ANSI

ON TA

NK

WA

T

E

R

SUP

P

LY

* CONDENS

ATE

DRAI

N

T

R

AP

P&

T

PRES

SURE

REDUCI

NG

FI

LL VAL

VE

CH

E

C

K

VA

LV

E

(T

YP.

)

HEATI

N

G

SYS

TEM

SUPPL

Y

SYST

EM

PUMP

P&

T

REL

IEF

VAL

VE (

T

YP.

)

HE

ATI

N

G

SYST

EM

RETU

RN

* 2"

MANUAL

SHUTOF

F

VAL

VE

GAS

SUP

P

LY

DI

RT TRAP

2)

S

H

ELL DRAI

N

VALVE

AND CONDENS

ATE DRAI

N

TR

AP

S

H

OULD BE ARRANGED TO PERMI

T

T

H

E FLUI

DS TO

DRA

IN

FREE

LY,

BY

GRAV

IT

Y

, TO A

4

) LOCATE

WATER I

N

LET AND OUTL

ET FI

T

T

IN

GS

(

i.e

. UNI

ONS

, ELB

O

W

S

, ETC.

) A MI

NI

MUM

OF

6

''

F

R

OM

BOI

LER

NO

RTHV

A

LE

, NJ

0

7

64

7

IN

T

E

R

N

A

T

IO

NA

L

, I

N

C.

AP

PD

.

DW

N

.B

Y

SC

AL

E

DA

T

E

DA

T

E

SD

NT

S

021506

A

E

RCO

SD-A-

672

TE

M

P

ERATURE GAUGE

P&

T

PRE

SSURE &

B

A

LANCI

NG VALVE

IS

OLA

T

IO

N VAL

VE

UNI

ON

Y S

T

R

A

IN

ER

LEG

E

ND

B

E

NCHMARK 2 MI

L

. BTU LOW NOx

GAS FI

RED BOI

L

ER

MUL

T

IP

LE UNI

T

IN

STAL

LATI

ON

6)

W

H

EN AVAI

LAB

LE GAS PRESSURE I

S

GREATER THAN 2.

0 PSI

G,

A LOCK-

U

P STYL

E

RE

GULATOR MUST BE I

N

STALL

E

D

D

O

W

N

ST

REAM OF

T

H

E

2

" MANUAL

SHU

T

OFF VALVE

TO BRI

N

G THE GAS PRESSURE DOW

N

TO

2

.0

PS

IG

.

RE

V

B

AT

MAXI

MUM

BTU/

HR I

N

PUT,

MAI

N

TAI

N

MI

NI

MUM

GAS

PRE

SSURE AT 5.

3"

W

.C.

(F

M GA

S T

R

AI

N

);

5

.5

"

W

.C.

(I

RI

).

MAX.

GAS PRESSURE

=

2

.0

PSI

G.

(SEE NOTE 6)

DRIP

T

R

A

P

* 2" M

A

NUA

L

S

HUTO

F

F

VAL

VE

M

A

IN

TA

IN

A

RE

G

U

L

A

TE

D

5.3

"

W

.C.

(F

M

), 5

.5 W

.C. (

IRI)

G

A

S P

R

ES

SU

R

E

AT

M

A

X

BT

U

/H

R

I

N

PU

T

G

AS SU

P

P

L

Y

(TO

B

O

IL

E

R

)

(S

E

E

N

O

TE

7

)

Di

agra

m

1

7

) A GAS

R

E

GULATOR I

S

MA

NDATORY FOR THE STATE

OF MASSAC

HUSETTS,

REGARDLE

SS OF

S

U

PPLY PRESS

URE.

SEE DI

A

G

RAM

1

Advertising