5. Appendix

14

12/28/2009 12:38 PM

This drawing
provides a general
illustration of the
DMX input/output
panel of a lighting
fixture.

Universal DMX Controller

Continue the link

Setting up a DMX Serial Data Link

3. Connect the (male) 3-pin connector side of

the DMX cable to the output (female) 3-pin
connector of the controller.

4. Connect the end of the cable coming from

the controller which will have a (female)
3-pin connector to the input connector of the
next fixture consisting of a (male) 3-pin
connector.

5. Then, proceed to connect from the output as

stated above to the input of the following
fixture and so

Returns Procedure

Returned merchandise must be sent prepaid and in the original packing; call tags will not be issued.

Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #).

Products returned without the RMA # will be refused. Call CHAUVET® and request an RMA # prior to

shipping the fixture. Be prepared to provide the model number, serial number and a brief description

of the cause for the return. Be sure to pack fixture properly; any shipping damage resulting from
inadequate packaging is the customer’s responsibility. As a suggestion, proper UPS packing or

double-boxing is always a safe method to use.

CHAUVET® reserves the right to use its own discretion to repair or replace product(s).

If you are given an RMA #, please include the following information on a piece of paper inside
the box:

1)

Your name

2)

Your address

3)

Your phone number

4)

The RMA #

5)

A brief description of the symptoms

Setting the Starting Address

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address

from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel

indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start

on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start

addresses so that the channels used do not overlap, and note the start address selected for future reference.

If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping to the
“Appendix” section and reading the heading “DMX Primer”. It contains very useful information that will help you

understand its use.