SECTION 5 - CARE AND MAINTENANCE

5.1

Carefully inspect the case and gasket for any visible cracks. Cracks may admit moisture, which could cause a malfunction.

In the event of any cracking or structural damage, the PLB should be immediately sent to Ameri-King Corp. for evaluation and repairs.

5.2

Do Not clean your with household cleaners and hydrocarbon materials such as gasoline, benzene, bleach, sanitizers,

soaps, etc., simply wipe your down with a damp cloth until clean.

5.3 Battery

Replacement

Power is provided by self contained long life batteries with a five-year recommended replacement cycle. See Factory Authorized
Service Center for replacement.

The battery Package must be replaced by the date indicated on the PLB. At each inspection, check the time remaining until
replacement is required. Batteries should be replaced if the has been activated for any use other than the self test.
Batteries should be replaced at an Authorized Battery Replacement Center for the warranty to remain in effect (if the 5 year warranty
has not expired). Services include: replacement of battery packs and disposal of expired lithium batteries, gasket and O-ring
examination and replacement if necessary, lubricated gaskets and O-ring, air pressure test to ensure water tight integrity, and a full
electronics diagnostic check.

NOTE: This unit is a life saving device and all repairs and replacements need to be made by Ameri-King Corp. or an authorized
Ameri-King Corp. battery replacement center to ensure the beacon will perform properly when called upon. Batteries can be
replace in the field if necessary (replacing your own batteries will void your warranty, contact Ameri-King Corp. for a replacement
battery dealer nearest you), however it is highly recommended to have your beacon serviced once you have returned from the field
to ensure the integrity of the beacon has not been compromised.

For the nearest location of an authorized Ameri-King Corp. service center, call 1-714-842-8555
or visit our website at

www.ameri-king.com

5.4

The Ameri-King AK-451-PLB contains 1 lithium battery pack.


5.5 Battery

Disposal

Please dispose of Lithium batteries in accordance with local waste disposal regulations


PLB PERSONAL LOCATOR BEACON

P-EPIRB / P-ELT / PLB


Operation: 24 hrs @ -20

o

C to +55

o

C (-4

o

F to +131

o

F)

Storage: -30

o

C to +70

o

C (-22

o

F to +158

o

F)

DO NOT OPEN, TAMPER, INCINERATE

OR RECHARGE BATTERIES

Replace batteries after use
or by date shown:
*Battery type: Lithium LiMn02

Lithium LiSO2










To Activate:
Lift & flip the switch to the “ON” position
Verify: The red “ON” light flashes 1 sec on, 4 sec off
Self Test: Press and Hold the switch to the “SELF-TEST”

position and wait for 25 sec

Verify: The red “ON” light must illuminate for 4 sec

then extinguishes. Wait for an additional 21 sec.

Pass: The red “ON” light must remain extinguished
Fail: The red “ON” light flashes. Please see Operation

Manual for detail fault code analysis