General information – CON-TECH CS2000-QD User Manual

Page 5

Advertising
background image

- 3 -

General Information

CS2000 Quick Start:

1.

Connect red wire to supply voltage

2.

Connect black wire to supply common

3.

For NPN Output - connect orange wire to black wire

For PNP Output - connect orange wire to red wire

4.

Connect white wire to your controller - refer to page 6 for wiring diagrams

5.

Turn on power

6.

Peel off a label and position the label backing (web) under the sensing area

7.

Depress the push-button until the yellow LED comes on (1 sec.), then release

8.

The yellow LED will begin flashing

9.

Move a label under the sensing area and the green LED will come on

10. The label sensitivity is now adjusted and the sensor should function correctly

11. The yellow LED indicates when label backing (web) is detected

12. The green LED indicates when label over label backing is detected

13. The red LED indicates when the output is active - NPN sinking or PNP sourcing

Advertising