3 pc-offset adjustment, 4 pc gain adjustment – Canon LV-7105E/D78-5133 User Manual

Page 64

Advertising
background image

2.3 PC-Offset Adjustment

1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.

[R-Offset adjustment]

3. Connect an oscilloscope to test point “TP2211R” (+) and chassis ground (-).
4. Enter to the service mode, select item no. “275” and change data value to adjust the

pedestal level and black level to be same level.

[G-Offset adjustment]

5. Connect an oscilloscope to test point “TP2221G” (+) and chassis ground (-).
6. Select item no. “276” and change data value to adjust the pedestal level and black

level to be same level.

[B-Offset adjustment]

7. Connect an oscilloscope to test point “TP2231B” (+) and chassis ground (-).
8. Select item no. “277” and change data value to adjust the pedestal level and black

level to be same level.

2.4 PC Gain Adjustment

1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.

[PC-R gain adjustment]

3. Connect an oscilloscope to test point “TP2211R” (+) and chassis ground (-).
4. Enter to the service mode, select item no. “30” and change data value to adjust “a” to

be 1.05 ±0.01Vp-p.

[PC-G gain adjustment]

5. Connect an oscilloscope to test point “TP2221G” (+) and chassis ground (-).
6. Select item no. “273” and change data value to adjust “a” to be 1.05 ±0.01Vp-p.

[PC-B gain adjustment]

7. Connect an oscilloscope to test point “TP2231B ” (+) and chassis ground (-).
8. Select item no. “274” and change data value to adjust “a” to be 1.05 ±0.01Vp-p.

Part 3: Adjustment

3-8

Pedestal level = Black level

Fig. 3-2