Installation -15 – Connect Tech DFlex-4/104 User Manual

Page 65

Advertising
background image

Chapter

4:

Appendix

E

-

RS-232

Options

4-15

DFlex-4/104 User's Manual, ver. 0.04

RS-232/Fast SLIM

The standard RS-232 SLIM is not fully functional with a DFlex-
4/104 adapter with J1 set for a maximum baud rate of 460K baud.
Only the RS-232/Fast Serial Line Interface Module (SLIM) is
fully functional with the DFlex-4/104 set for a maximum baud
rate of 460k baud.


Installation

The DFlex-4/104 adapter has two SLIM sockets that accept Serial
Line Interface Modules. SLIM 1 socket interfaces ports 1 and 2.
SLIM 2 socket interfaces ports 3 and 4. Please refer to Chapter
2: Hardware Installation
for the location of the SLIM sockets
and to Appendix D: SLIM Insertion/Removal for the proper
procedures to installing and removing SLIMs.

Your DFlex adapter and Serial Line Interface Module (SLIM) are
very sensitive to static electricity. Make sure that before you
remove them from the anti-static shipping bag, you wear an anti-
static wristband. When you remove them from the anti-static bag,
handle them only by the edges and place them on the anti-static
bag or an anti-static mat.

Please refer to Table 8 for the pinouts for the SLIM sockets found
on the DFlex-4/104 adapter.

Advertising