BAX Matrix Switching Systems—User Manual

13

5.0.3.2 RS-485 Communication Port

You can use the RS-485 port to control more than one BAX product.

The RS-485 Port as shown in Figure 5-7 below:

Figure 5-7

5.0.3.3 On/Off Switch Settings

Figure 5-8

A. DIP SW-8:RS-232/RS-485 switches ON/OFF

ON:RS-232 Enables Single System or RS-485 Serial Master

OFF:RS-485 Enables RS-485 Serial Slave

B. DIP sw-6/7:RS-485 Terminator ON/OFF

ON:Terminator ON

OFF:Terminator OFF

C. DIP sw 1 to 5 Setting(address setting)

The ID address determines the position of a BAX Matrix system. When multiple BAX

products are connected to one PC or when the Matrix products are serially connected, the ID

address decides which BAX product is to be controlled. Use the on/off switches 1, 2, 3, 4, 5 on

the rear panel to set the ID address as shown in Figure 5-2 below: