0 common problems and solutions – Avlink BAX-3088 User Manual

Page 30

Advertising
background image

BAX Matrix Switching Systems—User Manual

29

Model

Technical Parameters

BAX-3088 BAX-3084 BAX-3044

Max. Output Level

+22dBu(Balanced or Unbalanced Connection)

Control Types

Serial Control Connectors

RS-232,9-Pin Female D Type Connector

Baud Rate and Protocol

9600bps, no odd or even calibration address, 8bit

transmission address, 1bit stop address

Serial Control Port Structure TX,RX,GND

Control Procedures

《AV Matrix》

Specifications

Power

100VAC~240VAC,50/60Hz,International Auto-Switch Power

Temperature

Storage, Operating Temp.: -40℃~+85℃

Humidity

Storage, Usage Humidity: 10%~90%

Housing Measurements

485(L)X286(W)X140mm(H)

Product Weight

6250g

Media Faiure Interval

30,000 Hours

Warranty

One year warranty, lifetime maintenance

10.0 Common Problems and Solutions

1. What to do if the BAX matrix front panel keys switching not responsive?

Answer: The BAX matrix front panel keys employ scanning testing and require longer response

time. Press the keys for 2 seconds and then release. This way, key switching will be

responsive in operation.

2. What to do if matrix does not display or color display is abnormal after hot plug?

Answer: Switching of the matrix system goes through the IC chips. If the voltage difference

between the input signal equipment and the matrix equipment is too large, hot plug

could easily cause damage to the IC chips. Please turn off power to the system before

plugging or unplugging.

3. What to do if ghosting happens when RGB signals output to display?

Answer: Ghosting is often caused either by the projector, inferior cable quality or long

transmission distance. You are advised to adjust the projector or replace with better

quality cable.

4. What to do if loss of color reproduction happens or no video signal output?

Answer: Please check if connectors at both ends of the RGBHV signal cable are correctly

connected.

5. What to do if the serial port (usually refer to the computer serial port) fails to control the BAX