Gate Control Unit (GCU)
(not provided)

Assemble

Step 1: Remove GCU cover.

Step 2: Install 4 AA Alkaline
batteries (not provided).
(Lithium batteries
recommended for colder
environments.)

NOTE: This step applies only if more than one GCU
is being used.
Step 3: Up to four GCUs can be used. Each GCU will
need a different Identity. Set the Identity of the GCU
by changing the Dipswitches as shown in the chart
below.

GCU ID

Switch #1

Switch #2

1

OFF

OFF

2

ON

OFF

3

OFF

ON

4

ON

ON

Dipswitches

Learn
Button

Program

Press the Learn button on the
GCU for one second. The LED
will light for 20 seconds.

LED

?

?

?

?

Within 20 seconds enter Master PIN Number on
MUGAPLM:

Followed by GCU Identity as determined in Step 3:

1

2

3

4

OR

OR

OR

The GCU LED will blink 3 times indicating
programming is successful. NOTE: The relay will
engage.
If error tone is heard or GCU LED emits 3
double blinks, then programming has failed.
Repeat for additional GCUs.

Installation

Step 1: Replace GCU cover
and mount near gate operator
control box.

Step 2: Remove bottom panel
of GCU. Connect Terminal 10
on GCU to Common on gate
operator (shown below).
Connect Terminal 9 to Cycle on
gate operator (shown below).

“BEEP” “BEEP”

NOTE: If there is already an existing receiver proceed
to
Pre-Installed LiftMaster Receiver
(315Mhz Only) section.

1

3

2

4

5

6

7

8

9 10 11

DC

AC

+

-

COM

N/C

EXIT

SAFETY

EDGE

COMMON

OPEN

N/O

GATE OPERATOR

GCU