solids do not pass through the membrane. To calculate the % rejection, use the
following formula:

% Rejection = [(Feed TDS – Product TDS) / Feed TDS] x 100

Example:

98.5% = [(550-8.25)/550] x 100

NOTE: ALL TDS FIGURES MUST BE EXPRESSED IN THE SAME UNITS,

TYPICALLY PARTS PER MILLION (PPM) OR MILLIGRAMS PER LITER (MG/L).

AT-Series reverse osmosis systems are designed to reject up to 98.5% NaCl, unless
computer projections have been provided or stated otherwise.

The amount of permeate water recovered for use is expressed as a percentage. To
calculate % recovery, use the following formula:

% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100

Example:

23% = (0.35/1.50) x 100

NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS,

TYPICALLY GALLONS PER MINUTE (GPM).

SYSTEM REQUIREMENTS AND OPERATION GUIDELINES

PLUMBING

The membranes and high pressure pumps used on AT-Series systems require a
continuous flow of water with a minimum feed pressure of 45 psi, not to exceed 85°F.

FEED WATER CONNECTION

1. Locate the 1” FNPT solenoid valve feed water inlet.
(Figure 1A, Page 13)

2. Attach the inlet piping to the 1” FNPT solenoid valve feed water inlet.

3. Be certain that all of the components of the feed water are soluble at the

concentrations attained in the system.