9.2 Pump stop

The pump incorporates an electronic protec-
tive function that will stop the pump in case of

dry running

overtemperature

overloaded motor

seized-up motor/pump.

The pump will restart automatically after
30 minutes (for 24 hours) in case of any type
of fault if the auto-reset function is activated
(the green indicator light on the control panel
is on, see point 5 in the table of section
9.1 Control panel).

4

Pump on (green)

The indicator light is on when the pump is running.

5

Auto reset (green)

As standard, this function is activated on delivery.

When the indicator light is on, the auto-reset func-
tion is activated. The pump will automatically
attempt to restart every 30 minutes after an alarm/
fault over a period of 24 hours. After this period,
the pump will remain in the alarm condition.

When the indicator light is off, the auto-reset func-
tion is deactivated. The pump will not restart after
an alarm/fault.

The auto-reset function can be activated/deactivated
by pressing the on/off button for 5 seconds.

Note: When water is consumed, the pump will start
and stop automatically, whether the auto-reset light is
on or off.

6

Alarm (red)

The indicator light is on when the pump is in alarm
condition.

The alarm condition may have been caused by:

dry running

overtemperature

overloaded motor

seized-up motor/pump.

See section 9.2 Pump stop.

Note

The pump settings are stored.
After supply failure, the pump will
automatically revert to its previous
operating condition when the elec-
tricity supply is reconnected.