6. Operating conditions

6.1 Suction lift

The maximum suction lift of the pump can be
determined from the diagram, page 62.

Example:

If the suction lift is 10 ft, the length of the suc-
tion pipe must not exceed 72 ft.

MQ 3-35

MQ 3-45

Maximum flow rate [gpm]

22

Maximum pressure [psi]

51

65

Maximum system pressure [psi]

108

Maximum suction lift [ft]; see page 62

25

Minimum ambient temperature [°F]/[°C]

32/0

Maximum ambient temperature [°F]/[°C]

113/45

Minimum liquid temperature [°F]/[°C]

32/0

Maximum liquid temperature [°F]/[°C]

95/35

Net weight [lbs]

29

Sound pressure level [dB(A)]

< 70

Tank volume [oz]

13.5

Air pressure in tank [psi]

22 to 25

Connections

1" NPT

Priming and drain plugs

3/8" GAS