Technical Information

-20-

Q-Wash 260-LED User Manual Rev. 05

Troubleshooting Guide

Symptom

Cause(s)

Action(s)

Product is on
LEDs are off

Product defaulted

Configure product’s parameters

Faulty LED board

Send unit for repair

Faulty LED Driver board

Faulty LED Control board

Faulty Display board

Product and LEDs are on
Head fan is off

Faulty head fan

Send unit for repair

Faulty sensor or wiring

Send unit for repair

Pan movement problem

Faulty sensor

Send unit for repair

Faulty pan belt

Send unit for repair

Faulty pan motor

Send unit for repair

Faulty Display board

Send unit for repair

Tilt movement problem

Faulty tilt sensor

Send unit for repair

Faulty tilt belt

Send unit for repair

Faulty tilt motor

Send unit for repair

Faulty Display board

Send unit for repair

Circuit breaker/fuse
keeps tripping/blowing

Excessive circuit load

Reduce total load placed on the electrical circuit

Short circuit along the power wires

Check electrical wiring

Product does not power
up

No power

Check for voltage on outlet

Loose or damaged power cord

Check power cord

Blown fuse

Replace fuse

Faulty internal power supply

Send unit for repair

Product does not respond
to wired DMX or
responds erratically

Wrong DMX addressing

Check unit addressing

Damaged DMX cables

Check DMX cables

Wrong polarity on the controller

Check polarity switch settings on the controller

Loose DMX cables

Check cable connections

Non DMX cables

Use only DMX compatible cables

Bouncing signals

Install terminator as suggested

Long cable / low level signal

Install an optically coupled DMX splitter before a
long section of cable or right after the product
with the strong signal

Too many products

Install an optically coupled DMX splitter after unit
#32

Interference from AC wires

Keep DMX cables separated from power cables
or fluorescent/black lights

Faulty Display board

Send unit for repair

If you still experience technical problems after trying the above solutions or if you
need to send the unit for repair, contact CHAUVET® Technical Support.