Conventional systems, Heat pump systems – Braeburn 1220NC User Manual

Page 5

Advertising
background image

4

NOTES - Conventional Systems

[1] If batteries are installed the 24 Volt AC common connection is optional
[2] Remove factory installed jumper for dual transformer systems
[3] In dual transformer systems, transformer common must come from

cooling transformer

[4] If needed for system

Provide disconnect and overload protection as required.

2 HEAT / 1 COOL Single or Dual Transformer (1220NC Only)

Set System Type to CONV

Rh 24 Volt AC Power (heating transformer) [note 2]

Rc 24 Volt AC Power (cooling transformer) [note 2]

W1 Heat Relay Stage 1
W2 Heat Relay Stage 2
Y1 Compressor Relay Stage 1
G Fan Relay
C 24 Volt AC Transformer Common [note 1, 3]

Conventional Systems

(cont.)

Typical Wiring Configurations

NOTE: The “Installer Switch” option will be configured in the next step.

Heat Pump Systems

1 HEAT / 1 COOL - No Auxiliary Heat

Set Installer Switch to HP

Rh

24 Volt AC Power

Rc

Connected to Rh with supplied Jumper Wire

O or B Changeover Valve [note 2]
Y1

Compressor Relay

G

Fan Relay

C

24 Volt AC Transformer Common

[note 1]

2 HEAT / 1 COOL - Including Auxiliary Heat (1220NC only)

Set Installer Switch to HP

Rh

24 Volt AC Power

Rc

Connected to Rh with supplied Jumper Wire

O or B Changeover Valve [note 2]
Y1

Compressor Relay (1st stage heating/cooling)

W2

Auxiliary Heat Relay (2nd stage heating)

[note 3]

E

Emergency Heat Relay

[note 3]

G

Fan Relay

C

24 Volt AC Transformer Common

[note1]

(Continued)