1/6 OF FACEWIDTH
CLEAR ON
ENTERING SIDE

1/3

1/3

1/3

IDEAL

RUNS FROM

CENTER TOWARDS

LEAVING EDGE

MOVE GEAR

RUNS TO

ENTERING EDGE

DOES NOT ENTER

CENTER THIRD

MOVE GEAR

4.

Seals - To reassemble seals to unit, see Parts Service Steps on
Page 3.

5.

Motorized Coupling Adapter

Reassemble using the original dimensions determined under "General
Instructions" on Page 2.

6.

Final Inspection

A. Turn the gear train by hand as a final check.

B. Re-install reducer and accessories.

C. Fill reducer with the recommended oil to the appropriate level.

See the installation instructions supplied with the
reducer.

D. Spin test for three minutes and check for noise, leakage or rapid

temperature rise.

PREVENTATIVE MAINTENANCE

1.

After first week, check all external capscrews and plugs for tightness.

2.

Periodically, check oil level when gears are at rest. Add oil if needed. Do not fill above the recommended level because
leakage and overheating may result.

Fig. 6a: Entering and Leaving Sides

Fig. 6b: ACCEPTABLE

Fig. 6c: UNACCEPTABLE