Assembly, Warning, Caution – Champion Power Equipment 100105 User Manual

Page 13: Grounding, Add fuel

Advertising
background image

REV 100105-20140625

10

100105

ENGLISH

ASSEMBLy

Grounding

Your generator must be properly connected to an
appropriate ground to help prevent electric shock.

A ground terminal connected to the frame of the generator
has been provided on the power panel. For remote
grounding, connect of a length of heavy gauge (12 AWG
minimum) copper wire between the generator ground
terminal and a copper rod driven into the ground. We
strongly recommend that you consult with a qualified
electrician to ensure compliance with local electrical codes.

Failure to properly ground the generator can result in
electric shock.

WARNING

Our engines work well with 10% or less ethanol
blend fuels. When using blended fuels there are
some issues worth noting:

– Ethanol-gasoline blends can absorb more water

than gasoline alone.

– These blends can eventually separate, leaving

water or a watery goo in the tank, fuel valve and
carburetor.

– With gravity-fed fuel supplies, this compromised

fuel can be drawn into the carburetor and cause
damage to the engine and/or potential hazards.

– There are only a few suppliers of fuel stabilizer

that are formulated to work with ethanol blend
fuels.

– Any damages or hazards caused by using

improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not
covered by manufacture’s warranty.

It is advisable to always shut off the fuel supply,
run the engine to fuel starvation and drain the tank
when the equipment is not in use for more than 30
days.

NOTE

Add fuel Cont’d.

Add fuel

1. Use clean, fresh, regular unleaded fuel with a

minimum octane rating of 85 and an ethanol content
of less than 10% by volume.

2. DO NOT mix oil with fuel.
3. Clean the area around the fuel cap.
4. Remove the fuel cap.
5. Slowly add fuel to the tank. DO NOT OVERFILL. Fuel

can expand after filling. A minimum of 6.4 mm (¼ in.)
of space left in the tank is required for fuel expansion,
more than 6.4 mm (¼ in.) is recommended. Fuel can
be forced out of the tank as a result of expansion if it is
overfilled, and can affect the stable running condition of
the product. When filling the tank, it is recommended
to leave enough space for the fuel to expand.

6. Screw on the fuel cap and wipe away any spilled fuel.

Use regular unleaded gasoline with a minimum
octane rating of 85.

Do not mix oil and gasoline.
Fill tank to approximately 6.4 mm (¼ in.) below the
top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer
the fuel to the generator.
DO NOT fill fuel tank indoors.
DO NOT fill fuel tank when the engine is running or hot.
DO NOT overfill the fuel tank.
DO NOT light cigarettes or smoke when filling the
fuel tank.

CAUTION

Pouring fuel too fast through the fuel screen may
result in blow back of fuel at the operator while filling.

WARNING