Operation, Connecting electrical loads, Stopping the engine – Champion Power Equipment 100105 User Manual

Page 15: Starting the engine

Advertising
background image

REV 100105-20140625

12

100105

ENGLISH

Connecting Electrical Loads

1. Let the engine stabilize and warm up for a few

minutes after starting

2. Plug in and turn on the desired 120 Volt AC single

phase, 60 Hz electrical loads.

– DO NOT connect 3-phase loads to the generator.

– DO NOT connect 50 Hz loads to the generator.

– DO NOT overload the generator.

Connecting a generator to your electric utility
company’s power lines or to another power source
may be against the law. In addition this action,
if done incorrectly, could damage your generator
and appliances and could cause serious injury or
even death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage, please
notify your electric utility company immediately
and remember to plug your appliances directly
into the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company power
lines. You are responsible for ensuring that your
generator’s electricity does not feed back into the
electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility company
or a qualified electrician. Connections must isolate
generator power from utility power and must comply
with all applicable laws and codes.

NOTE

Stopping the Engine

1. Turn off and unplug all electrical loads. Never start

or stop the generator with electrical devices plugged
in or turned on.

2. Let the generator run at no-load for several minutes

to stabilize internal temperatures of the engine and
generator.

3. Turn the fuel valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped

the engine. This usually takes a few minutes.

5. Press the engine switch to the “OFF” position.
Important: Always ensure that the Fuel Valve and the
Engine Switch are in the “OFF” position when the engine
is not in use.

If the engine will not be used for a period of two (2) weeks
or longer, please see the Storage section for proper engine
and fuel storage.

NOTE

Starting the Engine

1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator.

Never start or stop the generator with electrical
devices plugged in or turned on.

3. Turn the fuel valve to the “ON” position.
4. Flip the engine switch to the “ON” position.
5. Move the choke lever to the “CHOKE” position.
6. Pull the starter cord slowly until resistance is felt and

then pull rapidly

7. Do not over-choke. As as soon as engine starts, move

the choke lever to the “RUN” position.

If the engine starts but does not run make certain
that the generator is on a flat, level surface. The
engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level
falls below a critical threshold.

NOTE

Keep choke lever in “Choke” position for only 1
pull of the recoil starter. After first pull, move choke
lever to the “Run” position for up to the next 3
pulls of the recoil starter. Too much choke leads to
sparkplug fouling/engine flooding due to the lack of
incoming air. This will cause the engine not to start.

NOTE

OPERATION

Advertising