Maintenance and storage, Danger, Caution – Champion Power Equipment 42432 User Manual

Page 17: Generator maintenance, Storage

Advertising
background image

REV 42432-20121015

14

42432

ENGLISH

MAINTENANCE AND STORAGE

Generator Maintenance

Make certain that the generator is kept clean and stored
properly . Only operate the unit on a flat, level surface in
a clean, dry operating environment . DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors .

Use a damp cloth to clean exterior surfaces of the generator .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris
from the generator .
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed .

Generator exhaust contains odorless and colorless
carbon monoxide gas .

To avoid accidental or unintended ignition of your
generator during periods of storage, the following
precautions should be followed:

– When

storing the generator for short or extended

periods of time make sure that the Engine
Switch and the Fuel Valve are set in the

OFF

position .

DANGER

Storage

The generator should be started at least once every 14
days and allowed to run for at least 20 minutes . For
longer term storage, please follow these guidelines .

Generator Storage

1 . Add a properly formulated fuel stabilizer to the tank .
2 . Be sure all appliances are disconnected from the

generator .

3 . Run the generator for a few minutes so the treated

fuel cycles through the fuel system and carburetor .

4 . Turn the fuel valve to the “Off” position .
5 . Let the generator run until fuel starvation has

stopped the engine . This usually takes a few minutes .

6 . The generator needs to cool completely before

cleaning and storage .

7 . Clean the generator according to the maintenance section .
8 . Change the oil .
9 . Remove the spark plug and pour about 1⁄2 ounce

of oil into the cylinder . Crank the engine slowly to
distribute the oil and lubricate the cylinder .

10 . Reattach the spark plug .
11 . Store the unit in a clean, dry place out of direct

sunlight .

Our engines work well with 10% or less ethanol
blend fuels . When using blended fuels there are
some issues worth noting:

– Ethanol-gasoline blends can absorb more water

than gasoline alone .

– These blends can eventually separate, leaving

water or a watery goo in the tank, fuel valve and
carburetor .

– With gravity-fed fuel supplies, this compromised

fuel can be drawn into the carburetor and cause
damage to the engine and/or potential hazards .

– There are only a few suppliers of fuel stabilizer

that are formulated to work with ethanol blend
fuels .

– Any damages or hazards caused by using

improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not
covered by manufacture’s warranty .

It is advisable to always shut off the fuel supply,
run the engine to fuel starvation and drain the tank
when the equipment is not in use for more than 30
days .

NOTE

Generator Storage Cont’d.

DO NOT use a garden hose to clean the generator .

Water can enter the generator through the cooling
slots and damage the generator windings .

CAuTION

Advertising