Controls and features continued – Chandler Limited Zener Limiter User Manual

Page 3

Advertising
background image

Controls and Features continued

At unity gain input with the INPUT switch on full you will get about 2% THD. If this is increased

to +4-5db, distortion will increase to around 5%, which is many, many times that of tape

and without clipping.

One excellent use of this is to patch the two Zener channels in series and use the first to Limit

and the second for THD. You can then use the OUTPUT control of the first channel to drive the

second into higher THD percentages while lower the output of the second to control overall

level. Very retro!

OUTPUT GAIN - Another 21-position gold contact switch set for +/-10db of gain control in 1db

steps. Use this for Gain make up when hard limiting or to drive the second channel into a higher

THD range when in THD mode as described above.

COMP/LIMIT - A very important control for tailoring the overall tone of the unit. COMP 1 is a

2:1 ratio with slower time constants that was originally designed by EMI engineers to emulate

the Altec 436/RS 124 EMI modified Altec compressors. Limit is much faster and designed to

emulate the response curves of the much loved Fairchild 660. COMP 2 is a new setting designed

to put you halfway between the two original settings and essentially gives you the compression

curve of COMP 1 with faster release times similar to LIMIT.

-8

-6

-4

-2

0

+2

+4

-10

+6

+8

+10

OUTPUT

COMP 1

COMP 2

LIMIT

Advertising