Troubleshooting, Safety opera tion maintenance setup – Chicago Electric 10" Compound Miter Saw with Laser Guide 69683 User Manual

Page 16

Advertising
background image

Page 16

For technical questions, please call 1-800-444-3353.

Item 69683

Troubleshooting

Problem

Possible Causes

Likely Solutions

Tool will not start. 1. No power at outlet.

2. Cord not connected.

1. Check power at outlet.
2. Check that cord is plugged in.

Tool operates

sporadically or

at low power.

1. Low power supply or

improper extension cords.

2. Worn or cracked

Carbon Brushes.

1. Check power supply and power cords.

2. Check Carbon Brushes. Replace if damaged or worn.

Wood burns at

ends when cut.

1. Dirty Blade.
2. Material is binding.

1. Clean Blade using blade cleaner or mineral spirits.
2. Check position of work material on Table. Material must

be flat, flush against Fence and supported on ends.

Material frays

or chips out.

1. Finished side is down.

2. Blade chipped or dull.
3. Blade inappropriate

for material.

4. Material is unsupported.

1. Keep finished side of material up or facing operator.

Bottom and back side are prone to chip out.

2. Check for damaged teeth. Sharpen or replace blade.
3. Check blade manufacturer’s recommendations for

material being cut. For cross cutting hard wood and for

precision cuts use a thin kerf blade with 60 or more teeth.

4. Use a thin piece of scrap material, such as 1/4″

plywood, underneath or behind the material to

support the edges of the material as it is being cut.

Blade binds,

slowing or

stopping saw.

1. Material is misaligned

on the saw or ends

are not supported.

2. Material is wet, contaminated

or inappropriate blade

is being used.

1. Material must be flat on table, flush against the fence and

supported on both ends.

2. Check condition of material and

check compatibility of blade to material.

Blade does not

cut completely

through

workpiece.

Depth Stop set too shallow.

Adjust Depth Stop Bolt for desired depth of cut.

Follow all safety precautions whenever diagnosing or servicing the tool.

Disconnect power supply before service.

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Advertising