Installation Instructions

Unit wiring diagram

This model operates at 115 volts except for the cutter
grid circuit which operates at 8.5 volts at 1 amp.

The compressor runs at all times except when the bin
thermostat becomes satisfied and opens up. This de­
energizes the system except for the transformer and
cutter grid.

Under

normal

operating

conditions,

when

the

evaporator reaches the preset temperature (-i-10° to
-3° F, depending on thickness of ice) the evaporator
thermostat

opens,

terminating

operation

of

the

fan

motor and pump motor. The hot gas solenoid and the
water valve solenoid are energized at this time and re­
main so until the evaporator reaches 38 -i- 2°F.

DANGER:
ELECTRIC SHOCK HAZARD disconnect power

before servicing unit. Maximum fuse size: 15
amps.

CUBELET CUTTER GRiDS

Start the unit by turning the service switch to

“ON” and opening the line water valve.

NOTE: Left is “OFF” — Middle is “ON” — Right
is

“CLEAN.”

In

“CLEAN”

position,

only

the

pump operates.

Check

condenser

fan

to

make

sure

it

is

revolving.

Water will not enter pump pan until freezing

plate gets cold and machine goes into a harvest
cycle.

Check for even water flow over freezing plate.

Unit must be level for proper operation.

-------g-C

Check for desired cube thickness and after 24

hours adjust if necessary. Maximum ice yield will
be obtained with ice thickness at V

2

” to

Replace grill.