INSTALLATION INSTRUCTIONS

(continued)

РЮШ» Ш

тят

(«entd)

Your range, like many other household

heavy and can зеШе into soft

u,

-Ante «С

floor coveri^s such as cushioned vinyl or

cai^eting. When moving the range on this type^
of flooring, use care, and foiiow these simple and
inexpensive instructions.

The range should be installed on a 1/4 mch thick

sheet of plywood (or similar material) as follows:

W hen the floor eovering ends at the front of the
rangOf

die area that the range will rest on should

be built up with plywood to the same level or
higher than the floor covering. Шз will aUow
the range to be moved for cleaning or servicing.

WlRiNG UUVbH
(SHOWN REMOVED)

STRAIN RELIEF BRACKETS
(PROVIDED WITH RANGE CORD ,
SET. NOT PART OF RANG^

\M

CONNECTOR
BLOCK

\

POWER

CORD

SfiP2

,

.

Pii^i ¥m

c®iigc?i®i

Use only a 3-conductor, or if required a 4-
conductor range cord set as noted below, 'píese
cord sets are provided with ring type terminals.

'The electrical rating of the cord must be 125/250
volts minimum, 40 amperes.

NO'TE: Only a 4-conductor cord is to be used

when the appliance is installed in a mobile home

or where local codes do not permit grounding

through the neutral.

SfiPS

1. Locate connector block at the bottom rear of

range and remove rear wiring cover.

2. Directly below the connector block is a hole

with a knockout ring for accommodating conduit
fittings. Brackets provided are used to support
the flexible cord strain relief, which must be

securely attached to the cord set.

СТЕР 4

Power Cord Installation—Insert screws
through power cord terminals so that the screws
pass through connector block terminals and

engage nuts. Tighten screws securely.

POWER CORD
RING TERfvliNAL

_

_ POWER

" CORD

CONNECTOR

BLU UK

TERMINAL

Cable Direct Installation—Clamp bare wires

between the connector block terminals and

movable nuts with screws tightened seoirely

1. Copper Wiring

MOVABLE
NUT

SCREW

CONNECTOR
BLOCK
TERMINAL

FLEXIBLE
CABLE

Connect the neutral or grounded wire of the
supply circuit to the neutral terminal of the
connector block, located in the center. 'The
power leads must be connected to the outside

(brass colored) terminals.

NEUTRAL

TERMINAL

Ü ^

GROUNDING STRAP

(GROUNDING TO RANGE)

WARNING: CONNECTOR BLOCK IS

APPROVED FOR COPPER WIRE

CONNECTION ONLY.

28