^WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in

death or fire.

WARNING:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.

4 in. (10.2 cm) heavy metai exhaust vent and ciamps must be
used. DURASAFE'^'^ venting products are recommended and are
available from your local Sears store or Sears Service Center.

DURASAFE^i^ vent products can be purchased from your deaier.
For further infomnation, please cali 1-800-4-MY-HOME®

(1-800-469-4663) or visit our Internet site at: www.sears.com.

■ The dryer exhaust must not be connected into any gas vent,

chimney, wall, ceiling, or a concealed space of a building.

■ Do not use an exhaust hood with a magnetic latch.

■ Do not install flexible metal vent In enclosed walls, ceilings or

floors.

■ Use clamps to seal all joints. Exhaust vent must not be

connected or secured with screws or other fastening devices
which extend into the interior of the duct. Do not use duct
tape.

IMPORTANT; Observe all governing codes and ordinances.

Improper venting can cause moisture and lint to collect
indoors, which may result in:

■ Moisture damage to woodwork, furniture, paint, wall­

paper, carpets, etc.

■ Housecieaning problems and health problems.

Use a heavy metal vent. Do not use plastic or metal foil vent.

Rigid metal vent is recommended to prevent cmshing and
kinking.

Flexible metal vent must be fully extended and supported when

the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.

An exhaust hood should cap the vent to prevent rodents and

insects from entering the home.

Exhaust hood must be at least 12 in. (30.5 cm) from the ground or
any object that may be in the path of the exhaust (such as

flowers, rocks or bushes, etc.).

If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or

flexible metal vent.

Oi

Typical exhaust installations
Typical Installations vent the dryer from the rear of the dryer.

Other Installations are possible.

1. Dryer

2. Elbow
3. Wall
4. Exhaust hood
5. Clamps

6. Rigid metal or flexible metal vent
7. Vent length necessary to connect elbows

8. Exhaust outlet

Optional exhaust installations

This dryer can be converted to exhaust out the right side, left

side, or through the bottom.

AWARNING

Fire Hazard

Cover unused exhaust holes with one of the
following kits:

279818 (white)

279915 (graphite)

279925 (biscuit)

Contact your local dealer.