PRODUCT DATASHEETS

Base Grille Water Filtration System Model WF-NLC250/NLC250

Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard S3 for the reduction of Lead, Cysts and Turbidity.

Capacity: 250 Gallons (946 Liters)
Service Fiow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance Reduction

U.S. ERA

Average

Maximum

Average

Minimum %

Average % NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction Number

Chlorine Taste/Odor

N/A

1.9 mg/L

N/A

0.04 mg/L

N/A

97.9%

994707

Particulate

N/A

610,000/mL*

N/A

154/mL

N/A

99.97%

994711

Contaminant

U.S. ERA

Average

Maximum

Average

Minimum %

Average % NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction Number

Cyst

99.95%**

89,250/mL*

6/mL

2.3/mL

99.993%

99.997%

994710

Turbidity

0.5 NTU

29 NTU

0.1 NTU

0.09 NTU

99.5%

99.69%

994710

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L***

0.001 mg/L

0.001 mg/L

99.4%

99.4%

994708

Lead: @ pH 8.5

0.015 mg/L

0.16 mg/L***

0.002 mg/L

0.001 mg/L

98.8%

99.4%

994709

Base Grille Water Filtration System Model WF-LC400/LC400

Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 400 Gallons (1514 Liters)
Service Fiow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance Reduction

U.S. ERA

Average

Maximum

Average

Minimum %

Average % NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction Number

Chlorine Taste/Odor

N/A

2.0 mg/L

N/A

0.04 mg/L

N/A

98%

994707

Particulate

N/A

610,000/mL*

N/A

154/mL

N/A

99%

994711

Contaminant

U.S. ERA

Average

Maximum

Average

Minimum %

Average % NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction Number

Cyst

99.95%**

89,250/mL*

6/mL

2.3/mL

99.993%

99.997%

994710

Turbidity

0.5 NTU

29 NTU

0.12 NTU

0.09 NTU

99.59%

99.69%

994710

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L***

0.001 mg/L

0.001 mg/L

99.4%

99.4%

994708

Lead: @ pH 8.5

0.015 mg/L

0.16 mg/L***

0.002 mg/L

0.001 mg/L

98.8%

99.4%

994709

■ Refer to the “Warranty” section for the Manufacturer’s limited

warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

3 0 - 1 2 0 psi (207 - 827 kPa)

Water Temperature

33“ - 100“F (0.6“ - 37.8“ C)

■ It is essential that operational, maintenance, and filter

replacement requirements be carried out for the product to
perform as advertised.

■ Model WF-NLC250 Change cartridge at least every 6-9

months. Use replacement cartridge NLC 250, part# 9902.
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.

■ Model WF-LC400 The filter monitor system measures the

amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life Is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400, part#
9902. 2000 suggested retail price of $39.95 U.S.A./S49.95
Canada.

■ The product Is for cold water use only.
■ Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after
the system.

■ Refer to the “Assistance or Service” section for the

Manufacturer’s name, address and telephone number.

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.

24

Advertising