TROUBLESHOOTING

Review this chart to find do-it-yourself solutions for minor performance problems. Any ser­

vice needed, other than those described in this owner’s manual, should be performed by
an authorized service representative.

A

WARNING

Electrical Shock Hazard

Disconnect electrical supply before servicing or cleaning the unit
Failure to do so could result in electrical shock or personal injury.

PROBLEM

Cleaner won't run.

POSSIBLE CAUSE

1. Unplugged at wall outlet

2. Tripped circuit breaker/biown fuse

at household service panel.

3. ON/OFF switch not turned ON,

POSSIBLE SOLUTION

1. Plug In firmly, push ON/OFF switch to

ON,

2. Reset circuit breaker or replace fuse

3. Push ON/OFF switch to ON,

Poor job of dirt
pick-up.

1. Full or clogged dust bag

2. Wrong pile height setting

3. Worn agitator

4. Clogged nozzle or dirt tube

5. Clogged hose.

6. Hole in hose

7. Broken/misplaced belt

8. Hose not inserted fully

9. Motor protection system activated.

10. Dirty fillers

1. Change dust bag, {page 13),

2. Adjust setting, (page 7).

3. Replace agitator, (page 21)

4. Clean nozzle area, (page 19).

5. Check for clogs, (page 19),

6. Replace hose.

7. Repiace/fix belt, (page 17),

B. Insert hose fully (page 10).

3. Check for clogs, (page 19)

10. Clean filters, (pages 14-15)

Cleaner picks up
moveable rugs or
pushes too hard.

1. Wrong pile height setting

1. Adjust setting, (page 7),

Light won’t work.

1. Burned out light bulb.

1. Change light bulb, (page 20)

Agitator does not

turn.

1. Broken belt

2. Bare floor selector in bare

floor setting

3. Belt installed Incorrectly

1. Replace belt, (page 16)

2. Switch selector to the carpet setting,

(page 7),

3. Check BELT CHANGING AND

AGITATOR CLEANING, (page 17),

Performance indicator,

some models, Is red.

1. Full or clogged dust bag,

2. Dirty filters

3. Clogged airflow passage ■

dirt tube, nozzle, hose.

4. Certain allachmenl tools.

1. Change dust bag, (page 13)

2. Clean fillers, (pages 14-15)

3. Clear clog from airflow passage,

(page 19),

4. Should return to normal when

tool is removed.

Air flow restricted
with attachment use.

Sound changes

1. Attachment use restricts

air flow,

2. New carpel fuzz clogged air path

1. Check ATTACHMENTS,

(page 8).

2. Check CLOG REMOVAL and clean

hose, (page 19),

Excessive noise as

vacuum is shut off.

1. Belt rubbing on carpet/bare floor

selector shaft,

22

1. Push selector all the way forward,

Advertising