Wire connection: direct wire – Kenmore ELITE OASIS 110.6707 User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

1.

2

.

Remove center silver-colored terminal block screw.

Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord under center,
silver-colored terminal block screw. Tighten screw.

A. Neutral ground wire

B. External ground conductor screw - Dotted line shows

position of NEUTRAL ground wire before being moved to

center silver-colored terminal block screw.

C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)

E. %" (1.9 cm) UL listed strain relief

3. Connect ground wire (green or bare) of power supply cord to

external ground conductor screw. Tighten screw.

A. External ground conductor screw
B. Neutral ground wire
C. Ground wire (green or bare) of power supply cord
D. ¥

4

" (1.9 cm) UL listed strain relief

E. Center silver-colored terminal block screw

F. Neutral wire (white or center wire)

4. Connect the other wires to outer terminal block screws.

Tighten screws.

t f

5. Tighten strain relief screws.

6

.

Insert tab of terminal block cover into slot of dryer rear panel.

Seoure cover with hold-down screw.

7. You have completed your eleofrical connection. Now go to

“Venting Requirements.”

4-wire connection: Direct Wire

IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3 wire
connections.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.

Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut VA" (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends
of wires info a hook shape.

When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.

1

.

2

.

Remove center silver-colored terminal block screw.

Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked
end (hook facing right) of the neutral wire (white or center

wire) of direct wire cable under the center screw of the
terminal block. Squeeze hooked ends together. Tighten
screw.

A. Neutral ground wire
B. External ground conductor screw - Dotted line shows

position of NEUTRAL ground wire before being moved to

center sliver-colored terminal block screw.

C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)

E.

¥4"

(1.9 cm) UL listed strain relief

10

Advertising
This manual is related to the following products: