WIRING SCHEMATIC

BACK OF TIMER

(PWA)

24V AC

Transformer

D“(

I | UT

Turbine

Sensor

ror^

GNC -'

+5

“T

MOTOR

JL

valve

motor

q

1

NO Position

Switch

NO

FACEPLATE^

Cusforar Ass/dfanc«

1-BOO-426-3345

w»mt<afmar*Wattf.t^

©

©

Keep this manual with your water softener. If repairs are needed, the service technician must have
the information on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.

ALWAYS MAKE THESE INITIAL CHECKS FIRST

Does the time display show the correct time of
day?
- - If display is blank, check power source to the
softener.
- - If time is flashing, power was off for over 24

hours. The softener resumes normal operation

but regenerations occur at the wrong time.

--If an error code (Example; Err3) shows in the

faceplate display, go to ALirOMATZC ELEC­

TRONIC DIAGNOSTICS, page 5-2.

Plumbing bypass valve(s) must be fully in ser­

vice position.

The inlet and outlet pipes must connect to the

softener inlet and outlet respectively.

Is the transformer plugged into a "live",
grounded wall outlet, and the power cable fas­
tened securely to the controller?

The valve drain hose must be free of kinks and

sharp bends, and not elevated over 8 ft. above the

I

m floor.

a Is there salt in the storage tank?

2 Is the brine tubing connected? Brine tubing con­

nects to nozzle venturi and brine valve assembly.

I

m (See page 6-3, key 083)

3 Is the brine valve float set right? (See page 5-4).
* Press the SELECT button two times to display

the hardness setting. Be sure it is the correct set­
ting for the household's water supply. (Make a

hardness test of the raw water and compare with
the hardness setting. Also test a soft water sam­

ple to verify if a problem exists.) Press the SE­
LECT button twice more to return to present time
in the display.

If you do not find the problem after making initial
checks, do the MANUAL INITIATED ELEC­
TRONIC DIAGNOSTICS, and the MANUAL AD­

VANCE REGENERATION CHECK.

5 - 1