Installation Instructions

Removing the Old Water Heater

©Tu rn “OFF” the gas supply to the water heater.

A WARNING

If the main gas line shutoff serving all gas appliances is

used, also shut “OFF” the gas at each appliance. Leave all
gas appliances shut “OFF” until the water heater installa­
tion is complete.

©

Disconnect the vent pipe from the draft hood where

they connect to the water heater. In most installations
the vent pipe can be lifted off aftet any screw or other

attached devices are removed. Dispose of the draft

hood. The new water heater has the draft hood which
must be used for proper operation.

©

^^Turn “OFF” the water to the water

heater. Some installations require that
the water be turned off to the entire
house.

(

3

)

Check a^ain to make sure the gas supply

is “OFF to the water heater. Then dis­

connect the gas supply connection from

the gas control valve.

© Artach a hose to the water heater drain

valve and put the other end in a floor
drain or outdoors. Open the water heater
drain valve. Open a nearby hot water

faucet which will relieve pressure in the

water heater and speed draining.

If you have copper piping to the water
heater, the two copper water pipes can
be cut with a hacksaw approximately 4"

away from where they connect to the
water heater. This will avoid cutting off

the pipes too short. Additional cuts can
be made later if necessary. Disconnect
the

temperature-pressure

relief

valve

drain line. When the water heater is
drained, disconnect the hose from the
drain valve. Close the drain valve. The
water heater is now completely discon­

nected and ready to be removed.

b. If you have galvanized pipe to the water

heater, loosen the two galvanized pipes
with a pipe wrench at the union in each
line. Also disconnect the piping remain­

ing to the water heater. These pieces

should be saved since they may be need­
ed when reconnecting the new water

heater. Disconnect the temperature-pres­

sure relief valve dram line. When the
water heater is drained, disconnect the

hose from the drain valve. Close the
drain valve. The water heater is now
completely disconnected and ready to be
removed.

AWARNING

A CAUTION

The water passing out of the drain valve may be extremely
hot. To avoid being scalded, make sure all connections are
tight and that the water flow is directed away from any
person.

Mineral buildup or sediment may have accumulated in the

old water heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could
cause staining.