Install the dehumidifier on a level floor strong

enough to support the unit with a full bucket

of water.

For best performance, allow at least 12-18

inches of air space on all sides of the unit for

good air circulation.

Keep all outside doors, windows, and other

openings closed when operating the

dehumidifier. Humid outdoor air will add to the

unit’s work load.

Install your dehumidifier in an area where the

temperature will not fall below 65°F (isti). At

temperatures below this, the coils can
become covered with frost, which may reduce

dehumidifying performance.

DEFROST CONTROL

When the defrost control senses frost build-up

on the evaporator coil, it will automatically shut

off the compressor. The fan will continue to run

to draw air across the coil and melt the frost

When the coil is defrosted, the compressor will

automatically restart and dehumidifying

resume.