Awarning, Gas piping with flexible connector, Gas piping with all black iron pipe to gas control – Kenmore 153.337002 User Manual

Page 16: Installation instructions (cont’d), Gas piping (cont’d)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions (cont’d)

Gas Piping (cont’d)

CORRECT GAS PIPE SIZE FOR

WATER HEATERS OPERATING ON NATURAL GAS

Based on Inlet Gas Pressures of 0.5 psig or Less and

a Pressure Drop of 0.3 inches Water Column.

(Based on a 0.60 Specific Gravity Gas)

TOTAL INPUT*

BTU/HR

DISTANCE TO METER, IN FEET

20

30

60

90 1 125

150

200

75,000

'h

Vi

Vi 1

1

1

100,000

V.

Vi

1 1

1

1

150,000

1

1 1 I7i

iVi

I7i

*Of all gas appliances in line.

A gas line of sufficient size must be run to the water heater.

Consult the latest edition of National Fuel Gas Code ANSI
Z223.1, also referred to as NFPA 54 and the gas company con­

cerning pipe size.

There must be;
• A readily accessible manuil shut off valve in the gas supply line

serving the water heater, and

• A drip leg (sediment trap) ahead of the gas control valve to help

prevent dirt and foreign materials from entering the gas control
valve.

• A flexible gas connector or a ground joint union between the

shutoff valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the

water heater. Use a soapy water solution, not a match or open

flame. Rinse off soapy solution and wipe dry.

Standard Models are for installation up to 3.300 feet above sea
level.
High Altitude Models are for installation from 3,300 to 5,500 feet
above sea level.
If a standard model is Installed above 3,300 feet or a high altitude

models is installed above 5,500 feet, the input rating must be
reduced at the rate of 4 percent for each 1,000 feet above sea level.
Contact your local Sears Service Center or gas utility for further
information.

AWARNING

The appliance and its gas connection must be ieak tested
before placing tiie appliance in operation.

AWARNING

’ The appliance and its individual shutoff valve must be discon­

nected from the gas supply piping system during any pressure
testing of the gas system at test pressures in excess of

%

pound per square inch (3.5kPa).

• The appliance must be isolated from the gas supply piping sys­

tem by closing its individual manual shutoff v^ve during any

pressure testing of the gas supply piping system at test pres­

sures equal or less than Vi pound per square inch (3.5kPa).

AWARNING

Use pipe joint compound or teflon tape marked as being
resistant to the action of petroleum [Propane (LP.)] gases.

GAS PIPING WITH

FLEXIBLE CONNECTOR

fq GAS SUPPLY PIPING

MANUAL
SHUTOFF
VALVE

FLEXIBLE GAS CONNECTOR

LABELED AS COMPLYING

WITH ANSI STANDARDS

GROUND JOINT
UNION (Optional)

GAS

CONTROL

VALVE

GAS PIPING WITH ALL BLACK IRON

PIPE TO GAS CONTROL

MANUAL

SHUTOFF

VALVE

GAS

CONTROL

VALVE

AWARNING

Contaminants in the gas lines may cause improper operation
of the gas control valve that may result in fire or explosion.
Before attaching the gas line be sure that all gas pipe is clean
on the inside. To trap any dirt or foreign materiiU in the gas
supply line, a drip leg (sometimes called a sediment trap)
must be incorporated in the piping. The drip leg must be

readily accessible. Install in accordance with the “Gas Piping”

section. Refer to the latest edition of the National Fuel Gas
Code, ANSI Z223.I, also referred to as NFPA 54.