Natural gas safety instructions – Kenmore 141.173373 User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Natural Gas Safety Instructions

Figure 1 (Natural gas m odel only)

IMPORTANT; your Kenmore Natural Gas Grill can­
not be converted to use LP Gas. Attennpting to do

so is extremely hazardous and will also void the grill
warranty.

Your natural gas griii is designed to operate on
natural gas only, at a pressure of 7" water column
(W.C.) (1/4 psi or 1.75 kpa), regulated at the
residential meter. Check with your gas utility
company for local gas pressure and with your
local municipality for building code requirements.

If your residential gas line pressure has not been

regulated to 7" W.C., contact your local gas utility
company for professional assistance.

It isrecommended thata Shutoff Valve be installed

at the gas supply source outdoors. Instali at a point
after the gas pipe exits the outside wall and before
the quick-disconnect hose, or install it at the point
before the gas line piping enters the ground.
See Figure 1.

Pi pe seali ng com poundorpipethread tape reastant
to the action of natural gas must be used on all male
pipe threads when making the connection.

• Disconnect your gas grill from fuel source when

the gas supply is being tested at high pressures.
This gas grill and its individual shutoff valve must
be disconnected from the gas supply pipe system
during any pressure testing of that system at
pressure in excess of 1/2 psi (3.5kpa).

• Turn off your gas grill when the gas supply is

being tested at low pressures. The grill must be
isolated from the gas supply pipe system by
closing itsindividual manual shutoff valve during
any pressure testing of the gas supply pipe
system at pressures equal to or less than

1

/2

psi

(3.5kpa).

GAS SUPPLY

DISCONNECT

Advertising
This manual is related to the following products: