Maintenance

CHANGE COLLET AND O-RING

1. Remove the collet and o-ring from the fitting with a

small screwdriver. Be careful not to scratch the internal

walls of the collet port. See Figures 27 & 28.

2. Clean collet port, lubricate and insert the o-ring seal

into the bottom of the port. See Figures 27 & 28.

3. Push the collet inward until it locks in place. See Figures

27 & 28.

Push o-ring seal into bottom of
port then follow with collet.

Fitting

O-Ring Seal

Collet

Change collet and o-ring

Figure 27

Collet (depress to
remove tubing)

Figure 28

CHANGE BATTERY

When the coin battery is first applied at initial start up,

the LED indicator light will flash in a red, amber, green

sequence. All timers and counters are reset to zero. In

order to reset the time and gallon count feature, push the

the button on the PWA and hold until the LED flashes and

release. The battery needs to be replaced at the time of

filter replacement. Use only lithium batteries (CR 2032 or

equivalent). Improper placement of battery could dam­

age electronics. Use care when inserting the battery to

align it correctly on PWA with the proper polarity.

* Reset button

Figure 29

NOTE:

It is not recommended that the RO assembly be

opened. If this becomes necessary, pay careful attention

to the layout of the parts and the routing of the tubing. It

will be necessary to assemble the unit exactly as shown

for the system to fit together and function properly.

Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com