Choose type of water fitting to install, Install cold water supply fitting, Optional pipe fittings – Kenmore REVERSE OSMOSIS 625.38556 User Manual

Page 8: Cold water supply connection, Step 1 - install supply water fitting

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Step 1 - Install Supply Water Fitting

CHOOSE TYPE OF WATER FITTING TO INSTALL

Check and comply with local plumbing codes as you

plan, then install o cold feed (supply) water fitting. Refer

to the Specifications page for supply water requirements.

The fitting must provide a leak-tight connection to the RO

1/4" tubing. A typical connection using the included water

supply fitting is shown in Figure 5.. An optional connection

using standard plumbing fittings (not included) is shown in

Figure 5B.

NOTE: Local code may dictate which type of water fit­

ting is used. Consult a plumber if you are not familiar

with local codes or plumbing procedures.

NOTE: Codes in the state of Massachusetts require

installation by a licensed plumber and do not permit the

use of saddle valves.

If you live in the state of Massachusetts, review plumb­

ing code 248-CMR of the Commonwealth of

Massachusetts before proceeding with the installation.

INSTALL COLD WATER SUPPLY FITTING

(Included with your package)

This fitting will be installed on the cold water pipe. The

fitting must provide a leak-tight connection to the Reverse

Osmosis 1/4" tubing. Locate the cold water line in the

sink cabinet. It is recommended, but not required, that the

cold water line be soft water.

Complete the following steps to install the water supply

fitting.

1. Close the water shut off valve that is immediately

before supply fitting and open faucets to drain water

from the sink cold water pipe.

2. Remove nut that connects the cold water faucet to cold

water plumbing.

3. Thread water supply fitting onto pipe and reconnect

nut to bottom of fitting.

OPTIONAL PIPE FITTINGS

(compression type shown)

NOTE: Be sure to turn off the water supply and open a

faucet to drain the pipe.

Complying with plumbing codes, install a fitting on the

cold water pipe to adapt 1/4" OD tubing. A typical con­

nection is shown in Figure 5B. If threaded fittings are

used, be sure to use pipe joint compound or thread seal­

ing tape on outside threads.

cold water

faucet stud

thread sealing

tape on threads

water supply fitting
(tee, feed adaptor)

1/4” green tubing to
Reverse Osmosis inlet

Cold Water Supply Connection

(using included water supply fitting)

Figure 5

Cold Water Supply Connection

(using compression fitting - not included) Figure 5B

Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com

Advertising