SECTION 4

OTHER THINGS TO KNOW

4A.

DIMENSIONS/SPECIFICATIONS

FIG. 12

BYPASS VALVES

Bypass valve(s) should always remain in soft
water service position. Position in "bypass"
only it needed for softener repairs.

SINGLE

PULL

OUT

for service

PUSH

IN

for

bypass

3 - VALVE

FOR SERVICE

close bypass valve

open Inlet & outlet valves outlet

FOR BYPASS

Lvi

open bypass valve

close Inlet & outlet valves

Bypass

Valve

Inlet

Valve

V 1

f

INCHES

CM

A

Salt Tank Height

40-1/4

102.2

B

Resin Tank Diameter (nominai)

9

22.7

C

Resin Tank Height (nominai)

40

101.6

D

Iniet-Outiet Height

41-1/2

105.4

E

Overaii Height

47

119.4

F1 Length

19-1/2

49.5

F2 Width

16-1/2

41.9

Distance between iniet-outiet
center iines

3-7/8

9.8

MODEL NO. 625.348600

TIMER HF CODE HF31

NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow rate/

pressure loss performance specifications. Performance specifications are validated by the Water Quality
Association (WQA). The rating decal is located on the rim, under the salt hole cover (see page 28).

WATER SUPPLY TO WATER SOFTENER

MINIMUM WATER SYSTEM FLOW (gpm) ........................................ 3
MINIMUM-MAXIMUM WATER PRESSURE (psi) ..................... 20-120
MAXIMUM WATER TEMPERATURE (°F) ..................................... 120
MAXIMUM WATER HARDNESS (gpg)........................................... 110
MAXMUM “CLEAR WATER” IRON (ppm) ..........................................7

SALT FOR WATER SOFTENER

TYPE OF SALT NEEDED............................................... Nugget/Pellet
ALTERNATE TYPE OF SALT .. Pure, evaporated, compacted

water softener salt

STORAGE CAPACITY (pounds)..................................................... 200

OTHERS

TYPE OF ION EXCHANGE MATERIAL (resin) High Capacity
AMOUNT OF RESIN (cu.ft.)............................................................. 1.0

REGENERATION (RECHARGE) CYCLE TIME (mln.)

FILL ....................................................................................... 3 - 1 3
BRINING/BR. RINSE..................................................................120
BACKWASH .................................................................................. 7
FAST RINSE...................................................................................3

TOTAL REGENERATION TIME

®........................ 1 3 3 - 1 4 3

gpm = gallons per minute psI = pounds per square Inch
gpg = grains per gallon

ppm = parts per million

® Does not Include CLEAN feature cycle times If set to ON.