To clean agitator, Important, To replace belt – Kenmore POWER-MATE 116.24614 User Manual

Page 17

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TO CLEAN AGITATOR:

NOTE; In order to keep cleaning efficiency
high and to prevent damage to your vacu­
um, the agitator must be cleaned every time
the belt is changed.

The agitator must also be cleaned accord­

ing to the following schedule:

Clean Agitator

every week

Vacuum Use

HEAVY -

(used daily)

MODERATE -

every month

(used 2-3 times/week)

LIGHT -

every 2 months

(used 1 time/week)

IMPORTANT

Disconnect cleaner from electrical outlet.

Check and remove hair, string and lint build­
up frequently in the Power-Mate® agitator
and end cap areas.

Remove any dirt or debris in the belt path

area or in the brush roller area.

Carefully remove any string or debris

located on the agitator, or end caps.

TO REPLACE BELT

1. Install new
belt over
motor drive,

then over

brush
sprocket.

NOTE: See

PARTS AND
FEATURES

for belt number.

Motor
Drive

Brush
Sprocket

Agitator End Cap

Cover

Base

2. Place agitator
assembly back

into Power­
Mate® .

3. Line up

front of
cover and

base. Rest

cover on
front edge of

base as
shown.

4. Rotate cover

back. Press

cover firmly until
side and rear
tabs snap into

place.

Side

Latch

Make sure there
is no gap
between the cover and base.

Rear

Latches

5. Turn Power-Mate® Upside down and
replace two (2) cover screws.

17

Advertising