Inst*::': . :■ ■ ■ ■ eilil'

AWARNING

Excessive Weight Hazard

Use two or more peopie to move and instaii dryer.

Faiiure to do so can resuit in back or other injury.

1. To protect the floor, use a large flat piece of cardboard from

the dryer carton. Place cardboard under the entire baok edge

of the dryer.

2.

Firmly grasp the body of the dryer. Gently lay the dryer on the

cardboard. See Illustration.

3.

Examine the leveling legs. Find the diamond marking.

4.

Screw the legs into the leg holes by hand. Use a wrench to

finish turning the legs until the diamond marking is no longer

visible.

5.

Place a carton corner post from dryer packaging under each

of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent or gas line.

For mobile home use

Gas dryers must be securely fastened to the floor at the time of
installation.

Mobile home installations require a Mobile Home Installation Kit.
For more information, please call

1-800-4-MY-HOME®

(1-800-469-4663).

nmm

yas i.#orirteciion

Remove the red cap from the gas pipe.

Using a wrench to tighten, connect the gas supply to the
dryer. Use pipe joint compound on the threads of all non-

flared male fittings. If flexible metal tubing is used, be sure
there are no kinks.

A. Flared male fitting
B. Non-flared male fitting

NOTE:

For LP gas connections, you must use pipe-joint

compound resistant to the action of LP gas. Do not use
TEFLON®t tape.

A combination of pipe fittings must be used to connect the
dryer to the existing gas line. Shown is a recommended
connection. Your connection may be different, according to
the supply line type, size and location.

A, Va flexible gas connector

B, %" dryer pipe
C, %" to ¥a pipe elbow
D, ¥i' pipe-to-flare adapter fitting

3.

Open the shutoff valve in the supply line. The valve is open
when the handle is parallel to the gas pipe.

A. Closed valve
B. Open valve

4.

Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.