■ A level floor with a maximum slope of 1" (2.5 cm) under entire

dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part No. 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.

■ For a garage installation, you will need to place the dryer at

least 18" (46 cm) above the floor. If using a pedestal, you will
need 18" {46 cm) to the bottom of the dryer.

Do not operate your dryer at temperatures below 45°F (7“C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.

NOTE:

No other fuel-burning appliance can be installed in the

same closet as a dryer.

Installation clearances

The location must be large enough to allow the dryer door to
open fully.

Dryer Dimensions

Custom undercounter installation - Dryer only

*Most installations require a minimum 5V2" (14 cm) clearance

behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”

Minimum installation spacing for recessed area, custom
undercounter or closet installation
The following dimensions shown are for the minimum spacing
allowed.

■ Additional spacing should be considered for ease of

installation and servicing.

■ Additional clearances might be required for wall, door and

floor moldings.

■ Additional spacing of 1" (2.5 cm) on all sides of the dryer is

recommended to reduce noise transfer.

■ For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.

■ Companion appliance spacing should also be considered.

Closet installation - Dryer only

(2.5 cm) (72.77 cm) (0 cm)

A

B

A. Side view - closet or confined area
B, Closet door with vents

*Side or bottom venting - additional

spacing recommended

Recessed or closet installation - Dryer on pedestal

0"*

(Ocm)

B

A. Recessed area
B. Side view - closet or confined area

* Additional spacing recommended

**Side or bottom venting - additional

spacing recommended