Converting the Lower

Element (cont'd)

2.

The convertible element is located behind the lower access

panel of the water heater. Remove the two screws securing
the access panel, and remove panel.

Installation Instructions (cont’d)

5. Remove the screws from terminal 2 of the element, and move

the looped end of the wire aside.

3. Remove the insulation block and pad.

6. The buss bar is labeled 5500 W. Place the buss bar over termi­

nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3.

4. Lower Element: Lift out the tab as shown to unclip the ter­

minal cover from the thermostat. The terminal cover can be
removed from the thermostat.

7- d'he wire removed from terminal 2 has a looped end. It must

remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.

i. Tighten terminals 2 and 3 to ensure proper electrical

connection.

A WARNING

Failure to tighten terminal screws can cause a fire which
can result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.