Service and Adjustment

Tank (Sediment) Cleaning

Sediment build-up on the tank bottom may create varying
amount of noise, and if left in the tank will cause premature
t^k felure. In some water areas, you may not be able to drain
all sediment deposits by simply draining the tank. In these cases
Mag £rad (part no. 23600) can be used to help remove the sedi­

ment deposits. This may be ordered from the Sears Service
Center. For ordering, refer to the “Parts Older List” section.

Venting System Inspection

At least once a year a visual inspection should be made of the
venting system. You should look for;

Obstructions which could cause improper venting. The com­
bustion and ventilation air flow must not be obstruacd.

Damage or deterioration which could cause improper venting

or leakage of combustion products.

Rusted nakes around top of water heater.

AWARNING

Chemical vapor corrosion of the flue and vent system may
occur if air for combustion contains certain chemical vapors.
Spray can propellants, cleaning solvents, refrigerator and air

conditioner refrigerants, swimming pooi chemicals, caldum
and sodium chloride, waxes, bleach, and process chemicds are
typical compounds vdiich are potentially corrosive.

AWARNING

Obstructed or deteriorated vent systems may present a serious

health risk or asphyxiation.

AWARNING

Be sure the vent piping is properly connected to prevent
escape of dangerous flue gasses which could cause deadly
asphyxiation.

AWARNING

If after inspection of the vent system you found sooting or

deterioration, something is wrong. Call the local gas utility to
correct the problem and dean or replace the flue and venting
before resuming operation of the w^r heater.

Burner Inspection

______________ AWARNING____________________

Do not use this appliance if any part of it has been under water.
Immediately call a Sears Sendee Technician to inspect the

appliance and to replace the gas control or any part of the
burner system vrhich has been under water.

At least once a yc^ a visual inaction should be of the

main burner and pilot burner. The drawing is for your reference.

You should check for sooting which is not normal and will
impair proper combustion.

AWARNING

Soot build-up indicates a problem that requires correction

u*e- Turn “OFF’ gas to water heater and leave

*OFr ’ until repairs are made, because follure to correct the

cause of the sooting can result in a fire or explosion causine

DEATH, SEMOUS BODILY Ih^URy, OR PftOPERTY DAMAGE

Burner Cleaning

In the event your burner needs cleaning, use the following

instructions:

°

If inspection of the burner shows that cleaning is required, turn
the gas control knob dockwise

to the “OFF” position,

depressing siighdy.

NOTE« The knob cannot be turned from “PILOT” to “OFF”

unless knob is depressed slightly. DO NOT FORCE.

Loose deposits on or around the burner can be removed by care­

fully using the hose of a vacuum deaner inserted through the
access door of the water heater. If the burner needs to be removed
for additional deaning, call the Sears Service Center to remove
Md dean the burner and correct the problem that required the
burner to be deaned.

L.R Gas Control Valve & Burner

Assembly Replacement

Information

AWARNING

PROPANE (LP.) GAS CONTROL VALVE AND BURNER

ASSEMBLY REPLACEMENT INFORMATION.

For Propane (L.P.) Gas Models Only:

Your water heater is equipped with a Propane (LP.) gas
control valve and a main burner assembly vrith left hand
threads for the following fittings and their connections.

(1)

The

connection

between

the

manifold

and

the

gas control valve (A to B) are left hand threads.

(2)

The

connection

between

the

main

burner

ori­

fice and

the

manifold (C to D) are left hand

threads.

For

ordering

these

replacement

parts,

please refer to the “Parts Order List” section of

this manual.

20

Advertising