Safety Precautions

AWARNING

AWARNING

A gas water heater cannot operate properly widiout the

correct amount of air for combustion. Do not install in a
confined area such a closet, unless you provide air as
shown in the “Locating The New Water Heater” section.
Never obstruct the flow of ventilation air. If you have any
doubts or questions at all, call your gas company. Failure
to provide die proper amount of combustion air can result
in a fire or explosion and can cause DEATH, SERIOUS

BODILY INJURY, OR PROPERTY DAMAGE.

This water heater must not be installed directly on car­

peting. Carpeting must be protected by a metal or wood
panel beneath the appliance extending beyond the full
width and depth of the appliance by at least 3 inches
p6.2mm) in any direction, or if tiie appliance is instidled
in an alcove or closet, the entire floor must be covered by
the panel. Failure to heed this warning may result in a
fire hazard.

AWARNING

HOTTER

WATER

CAN

SCALD:

Water

heaters

are

intended to produce hot water. Water heated to a tem­
perature which will satisfy ciothes wnishing, dish washing,

and other sanitizing needs can scald and permanently
injure you upon contact. Some people are more likely to
be permanently injured by hot water than others. These

include the elderly, children, the infiryn, or physlcally/men-

tally handicapped. If anyone using hot water in your home
fits into one of these groups or

V

there is a local code or

state law requiring a certain temperature water at the hot

water t:q>, then you must take special precautions. In addi­
tion to using the lowest possible temperature setting that

satisfies your hot water needs, a means such as a mixing

valve, should be used at the hot water taps used by these

people or at the water heater. Mixing valves are available
at plumbing supply or hardware stores. Follow manubic-
turers instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
‘Hemperature Regulation” section in this manual.

AWARNING

Soot build-up indicates a problem that requires correc­

tion before Airdier use. Turn “off” gas to water heater

and leave "off” until repairs are made, because foilure to
correct the cause of the sooting can result in a fire or
explosion

causing

DEATH,

SERIOUS

BODILY

INJURY,

OR PROPERTY DAMAGE.

AWARNING

VENT DAMPERS - Any vent damper, whether it is operat­
ed thermally or otherwise must be removed if its use

inhibits proper drafting of the water heater.

Thermally

Operated

Vent

Dampers:

Gas-fired

water

heaters having thermal efficiency in excess of 80% may
produce a relatively low flue gas temperature. Such tem­
peratures may not be high enough to properly open ther­
mally operated vent dampers. This would cause spill^e of

flue gases and may cause carbon monoxide poisoning.

Vent dunpers must bear evidence of certification as com­
plying

with

the

latest

edition

of

American

National

Standard ANSI Z2I.68 (ANSI Z2I.66 & 67, respectively,
cover

electrically

and

mechanically

actuated

vent

dampers). Before installation of any vent damper, consult
your local Sears Service Center or the gas utility for fur­
ther information.

AWARNING

• The appliance and its individual shutoff valve must be dis­

connected from the gas supply piping system during any
pressure testing of the gas system at test pressures in
excess

oi

1/2 pound per square inch (3.5kPa).

•The appliance must be isolated from the gas supply pip­

ing sy^m by closing its individual manuj shutoff valve
during any pressure testing of the gas supply piping sys­
tem at test pressures equal or less than

1/1

pound per

square inch (3.5 kPa).____________________________

AWARNING

BEFORE

LIGHTING

[PROPANE

(L.P.)

GAS

WATER

HEATERS]: Propane (LP.) gas is heavier than air. Should

there be a leak in the system, the gas will settle near the
ground.

Basements,

crawl spaces,

skirted areas under

mobile homes (even when ventilated), closets and areas
below ground level will serve as pockets for the accumula­

tion of this gas. Before attempting to light or relight the
water heater^ pilot or turning on a nea^y electri^ light

switch, be absolutely sure there is no accumulated gas in
the area. Search for odor of gas by sniffing at ground level
in the vicinity of the appliance. If odor is detected, follow
steps indicated at "For Your Safety” on the cover page of
this manual then leave the premises.

AWARNING

Chemical vapor corrosion of the flue and vent system

may occur if air for combustion contains certain chemical

vapors. Spray can propellants, cleaning solvents, refrigera­
tor

and

air

conditioner

refrigerants,

swimming

pool

chemicals, calcium and sodium chloride, waxes, bleach,
and process chemicals are typical compounds which are
potentially corrosive.

AWARNING

Obstructed or deteriorated vent systems may present a
serious health risk or asphyxiation.

Safety Precautions continued on page 4