Troubleshooting, œntinued – Honeywell MAGIC STAT CT3100 User Manual

Page 12

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Troubleshooting, œntinued

PROBLEM

CHECK

ACTION

Display goes

blank for several
minutes during long

furnace burn cycle,
then recovers.

—air filter and fan belt.

Replace if necessary.

—possible power interruptions

during part of furnace cycle.

May require isolating relay to

eliminate power interruptions. See

Table 1 in installation manual form

number 69-8024.

No heat.

—pilot flame. May be out.

Relight pilot flame per furnace
manufacturer's instructions.

—fuse or circuit breaker.

If fuse is blown or breaker tripped,

replace or reset.

No cooling.
Note: The CT3100

—system switch. May be in OFF

or HEAT position.

Move switch to COOL position.

is not designed

for cooling-only

—fuse or circuit breaker.

If fuse is blown or breaker tripped,

replace or reset.

systems.

—condenser switch position.

Located outdoors and may be

turned OFF.

Move to ON position.

20

continued

Troubleshooting, continued

PROBLEM

CHECK

ACTION

No cooling,

(continued)

—thermostat connections.

Turn OFF power to cooling system
and furnace. Check for correct

terminal hookups. Repair any
frayed or broken wires. Firmly
tighten all terminal screws.

—other.

Contact a qualified service tech­

nician for assistance.

Time button

advances to next
program point
instead of by

15-minute

increments.

—number of temperature settings

programmed; thermostat will

take up to six.

Erase one setting before adding
another.

continued

21

69-8023—2

Advertising