PROGRAMMING AND SETTING

You will program your thermostat once for the entire year, entering your temperatures for both

the heating and air conditioning seasons. You may enter heating temperatures between 54° F and

82° F, and cooling temperatures between 62° F and

88

° F. A cool setting above

88

° F (HI) leaves

the cooling off at any temperature.

The first program you set will be automatically copied into all 7 days. You may make changes later

to your program for the weekend. This typical weekday schedule suggests setting for atypical week;
fill in the blanks with your preferred schedule and use as a guide when programming.

Typical

Suggested

Your Time

Suggested Program

Your Program

Activity

Time Schedule

Schedule

Temperatures (° F)

Temperatures

Heat

Cool

Heat Cool

Wake up

6:15 AM

68

74

Leave Home

7:30 AM

54

80

Arrive Home

5:00 PM

68

74

After Dinner

8:00

PM

72

74

Retire

10:45 PM

60

80

Program A Typical Weekday Schedule

7ou may program the CT3100 in your hand
before installation, oronthewall. If programming
Defore installation, the display will go blank dur-

ng programming if no buttons are pressed for

several seconds. There is no need to start over;
proceed where you left off, and the display will

eappear. However, if the CT3100 is already

vired to the wall when
irogramming, the dis-
)lay will stay on.

^ress reset button
jnder battery cover to
:lear out any program
>r setting already in the
nemory.

Move the system switch

to HEAT. The display will
show current room tem­
perature with MANUAL.

MANUAL indicates that

even though there is no
program in the thermostat,
it can be used as a manual

thermostat by selecting a
temperature using the UP

and

DOWN

buttons when

the cover is
closed.

SYSTEM SWITCH

Heat

Off

Cool

nn

%Lf

®®©®©©©

69

-