INSTALLATION INSTRUCTIONS

3

Keep a firm grip on the air conditioner, carefuiiy

piace the unit into the window opening so the
bottom of the air conditioner frame is against the

window sill (FIG.6).Carefully close the window behind the
top rail of the unit.

FiG.6

Extend the side panels out against the window

frame (FIG.7).

5

Place the frame lock between the frame

extensions and the window sill as shown

(FIG.8). Drive 3/4 *( 19mm) locking

screws through the frame lock and into the sill
(FIG.9). NOTE: To prevent window sill from
splitting, drill 1/8'(3 mm) pilot holes before
driving screws.

Drive 3/4'(19mm) locking screws

through frame holes into window sash

(FIG.10).

FIG. 10

8

To secure lower sash in place, attach right angle
window lock with 3/4' (19 mm) screw as shown

(FIG. 11).

FIG. 11

Cut foam seal and insert in the space

between the upper and lower sashes

(FIG.12).

If AC is Blocked by Storm Window

Add wood as shown in FIG.13, or remove storm

window before air conditioner is installed.

FIG. 13

STORKS WINDOW

FRAME

OR OTHER
OBSTRUCTION

1 1/2” MIN

(38 mm)

BOARD
THICKNESS
AS REQUIRED,
-OR PROPER
PITCH TO
REAR, ALONG
ENTIRE SILL.
FASTEN WITH
NAILS OR
SCREWS,

If Storm Window Frame must remain, be sure the

drain holes or slots are not caulked or painted shut.

Accumulated Rain Water or Condensation must be

allowed to drain out.

Removing AC From Window

3|c Turn AC off, and disconnect power cord.
^ Remove sash seal from between windows,

and unscrew safety lock.

^ Remove screws installed through frame and

frame lock.

3|c Close(slide) side panels into frame.

Keeping a firm grip on air conditioner, raise

sash and carefully “rock” air conditioner
backward to drain any condensate water in
base of unit. Be careful not to spill any
remaining water while lifting unit from

window. Store parts WITH air conditioner.

Advertising