Installation Step 10

Install the Safety Reversing Sensor
(Receiving and Sending Eyes)

18

FLOOR MOUNT (Right Side)

WALL MOUNT (Right Side)

DOOR TRACK MOUNT (Right Side)

Indicator
light

Lens

Lip

Sensor

Bracket

Door

Track

Sensor

Bracket

Optional

Extension

Bracket

(See Accessories)

Lens

Indicator

light

Attach with

concrete anchors

(not provided)

Inside

Garage

Wall

Indicator

light

Sensor

Bracket

Lens

Optional

Extension

Bracket

(See Accessories)

Inside

Garage

Wall

(Provided with

Extension

Bracket)

(Provided with

Extension Bracket)

(Provided with

Extension Bracket)

(Provided with

Extension

Bracket)

Wing Nut (2)

Insulated Staples (20)

Carriage Bolt

1/4"-20x1/2" (2)

Hardware Shown Actual Size

Figure 4

Figure 2

Figure 3

INSTALLING THE BRACKETS

Be sure power to the opener is disconnected.
Install and align the brackets so the sensors will face
each other across the garage door, with the beam
from 4 – 6" above the floor.

They may be installed in one of three ways, as
follows.

Garage door track installation (preferred):

• Slip the curved arms over the rounded edge of each

door track, with the curved arms facing the door.
Snap into place against the side of the track. It
should lie flush, with the lip hugging the back edge
of the track, as shown in Figure 2.

If your door track will not support the bracket
securely, wall installation is recommended.

Wall installation:

• Place the bracket against the wall with curved arms

facing the door. Be sure there is enough clearance
for the sensor beam to be unobstructed.

• If additional depth is needed, an extension bracket

(see Accessories) or wood blocks can be used.

• Use bracket mounting holes as a template to locate

and drill (2) 3/16" diameter pilot holes on the wall at
each side of the door, from 4–6" above the floor.

• Attach brackets to wall with lag screws (not

provided).

• If using extension brackets or wood blocks, adjust

right and left assemblies to the same distance out
from the mounting surface. Make sure all door
hardware obstructions are cleared.

Floor installation:

• Use wood blocks or extension brackets (see

Accessories) to elevate sensor brackets so the
lenses will be 4-6" above the floor.

• Carefully measure and place right and left

assemblies at the same distance out from the wall.
Be sure all door hardware obstructions are cleared.

• Fasten to the floor with concrete anchors as shown.