Only the pressure regulator and hose assembly supplied

with the grill should be used. Any replacement pressure,

regulator and hose assembly must be specified by the grill

manufacturer.

This is a liquid propane configured grill.

Do not attempt to use a natural gas supply unless the grill

has been pre-configured for natural gas use.

Total gas consumption (per hour) of 720-0289 grill with all

burners on “HI”:

Main burners

40,000 Btu/hr.

Sear burner 18,000 Btu/hr

Side burner 12,000 Btu/hr.

Rotisserie burner

15,000 Btu/hr.

Total

85,000 Btu/hr.

The installation of this appliance must conform with local

codes or, in the absence of local codes, with the national

fuel gas code, ANSI Z223.1 Installation in Canada must be

in accordance with the Standard CAN/CG A-B149.2

(installation code for gas burning appliances and

equipment) and local codes.

LP Gas Cylinder Requirements (20lb.Cylinder)

A dented or rusty LP Gas Cylinder may be hazardous and

should be checked by your LP supplier. Never use a

cylinder with a damaged valve. The LP gas cylinder must be

constructed and marked in accordance with the

specifications for LP gas cylinders of the U.S. Department

of Transportation (DOT), or the National Standard of

Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for

Transportation of Dangerous Goods; and Commission.

The 20lb. cylinder must be provided with a shut off valve

terminating in an LP gas supply cylinder valve outlet

specified, as applicable, for connection type QCC1 is the

standard for compressed gas cylinder valve outlet and inlet

connection ANSI/CGA-V-1.

The cylinder supply system must be arranged for vapor

withdrawal. The cylinder must include a collar to protect the

cylinder valve.

Manifold pressure: (operating): 10” water column (W.C.),

(non-operating): 11.2” water column (W.C.).

LP Gas Cylinder must be fitted with Overfill Protection Device

(OPD).

LP GAS HOOK-UP:

Ensure that the black plastic grommets on the LP cylinder

valve are in place and that the hose does not come into

contact with the grease tray or the grill head.

CONNECTION:

Your grill is equipped with gas supply orifices for use only with

liquid propane gas. It is also equipped with a high capacity

hose/regulator assembly for connection to a standard 20lb. LP

cylinder (18-1/4” high, 12-1/4” diameter).

To connect the L.P. gas supply cylinder:

1. Make sure tank valve is in its full off position (turn

clockwise to stop).

2. Check tank valve to ensure it has proper external male

threads (type 1 connection per ANSIZ21.81).

3. Make sure all burner valves are in the off position.

4. Inspect valve connections, port and regulator assembly.

Look for any damage or debris. Remove any debris.

Inspect hose for damage. Never attempt to use damaged

or obstructed equipment. See your local LP gas dealer for

repair.

5. When connecting regulator assembly to the valve, hand

tighten the nut clockwise to a complete stop. Do not use a

wrench to tighten. Use of a wrench may damage the

quick coupling nut and result in a hazardous condition.

6. Open the tank valve fully (counterclockwise). Use a soapy

water solution to check all connections for leaks before

attempting to light the grill. See below. If a leak is found,

turn the tank valve off and do not use the grill until a local

LP gas dealer can make repairs.

To disconnect LP gas cylinder:

1. Turn the burner valves off.

2. Turn the tank valve off fully (turn clockwise to stop).

Detach the regulator assembly from the tank valve by turning

the quick coupling nut counterclockwise

GAS HOOK-UP