15

ˆ Specified clearance maintained 24” from

combustibles.

ˆ All internal packaging removed.
ˆ Knobs turn freely.
ˆ Burners are tight and sitting properly on orifices.
ˆ Pressure regulator connected and set for 11.2”

W.C. LP gas. Gas connections to grill using

hose & regulator assembly provided (pre-set for

11.0” water column).

INSTALLER FINAL CHECK

ˆ Unit tested and free of leaks.
ˆ User informed of gas supply shut off valve

location.

PLEASE RETAIN THESE INSTRUCTIONS FOR

FUTURE REFERENCE.