Craftsman 919.16558 User Manual

Page 19

Advertising
background image

6.

Remove the outlet pressure
gauge, tank pressure gauge, and
adapter from the regulator.

7.

Remove the regulator.

8.

Apply pipe sealant tape to the
nipple.

9.

Assemble the regulator and
orient as shown.

NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.

10. Reapply pipe sealant to outlet

pressure gauge, tank pressure
gauge, and adapter.

11. Reassemble outlet pressure

gauge, tank pressure gauge, and
adapter. Orient outlet pressure
gauge and tank pressure gauge
to read correctly. Tighten adapter
with wrench.

12. Rotate pressure switch assemble

into correct position.

13. Replace console cover and

regulator ring.

19- ENG

A00854

To Replace Regulator

1.

Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.

2.

Set the On/Auto/Off lever to
"OFF" and unplug unit.

3.

Remove the regulator ring and
remove the console cover.

4.

Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.

5.

Using an adjustable wrench,
rotate the pressure switch
assembly as shown.

Regulator

Adapter

Tank
Pressure
Gauge

Outlet
Pressure
Gauge

Regulator
Ring

Cover

12. Replace the outlet tube and

tighten nuts.

13. Replace shrouds and console.
14. Perform the Break-in Procedure.

See "Break-in Procedure" in the
Operation section.

Regulator

Arrow

Advertising